
A Study to Compare the Press Fit Condylar (P.F.C.) Sigma Rotating-platform High-flexion (RP-F) Versus...
Knee OsteoarthritisThe main objective of this study is to determine if the P.F.C. Sigma RP-F Knee delivers a greater post-operative range of motion (ROM) compared with the P.F.C. Sigma RP Knee in primary TKA. The secondary objectives of this investigation are to evaluate the clinical and patient outcomes and survivorship associated with the DePuy P.F.C. Sigma RP-F and RP Posterior Stabilised (PS) Knee over 5 years.

Long-term Study of The Press Fit Condylar (P.F.C.) Sigma Total Knee Replacement System
Knee OsteoarthritisThe main purpose of this study is to record information from clinical and radiographic examinations and patient assessment questionnaires before surgery and at suitable postoperative intervals to assess the functioning and symptomology of each knee following surgery. In addition, any adverse events or complications are to be recorded, and any device failures or early revisions are to be recorded and reported directly to the Sponsor. The data are to be used in an evaluation of the performance of the P.F.C. Sigma knee implants over a minimum of 5 years.

Multi-Centre Study to Assess the Long-term Performance of the DePuy ASR™ System in Resurfacing and...
Rheumatoid ArthritisOsteoarthritis6 moreThe purpose of this study is to monitor the performance of a large metal-on-metal bearing from the DePuy ASR™ System in the treatment of patients with hip joint disease requiring hip resurfacing surgery or a total hip replacement. Patients who enter the study will be evaluated at regular intervals following hip surgery using patient, clinical and x-ray assessments. The Study was terminated with effect from 30th November 2011 following the completion of 2 year follow up assessments for those patients remaining in the study. Please note that prior to this decision DePuy voluntarily recalled the ASR products on 24 August 2010. Additional information regarding this voluntary recall and the follow-up of patients affected by the recall can be found at the following links http://www.mhra.gov.uk/Publications/Safetywarnings/MedicalDeviceAlerts/CON155761 and http://www.depuy.com/countries_list.

Trial to Assess Efficacy and Safety of Lacosamide in Subjects With Osteoarthritis of the Knee
OsteoarthritisThe purpose of this trial is to evaluate the effectiveness, safety and tolerability of lacosamide (LCM) 400mg/day in treating the signs and symptoms of osteoarthritis of the knee.

Prescription Methods Assessment Project (PMAP)
OsteoarthritisGastroesophageal Reflux DiseaseThe purpose of this study is to evaluate whether a novel prescription method (N-of-1 intervention)can be successfully integrated into primary care practices and to examine the effects of this prescription method on selected patient health outcomes (e.g.., medication compliance, medication costs, symptom management, satisfaction of physician/patient visit, etc.) in patients with a uncontrolled or new diagnosis of Osteoarthritis or Chronic Heartburn (GERD).

A Study Of The Effect Of CE-224535 On Knee OA (Osteoarthritis) Pain
OsteoarthritisCE-224535 is a new medication being developed as an analgesic and anti-inflammatory agent for the treatment of the signs and symptoms of osteoarthritis (OA). The purpose of this study is to evaluate the analgesic and anti inflammatory efficacy and safety of CE 224,535 versus placebo and naproxen treatment in patients with OA knee pain.

Multicenter Orthopaedic Outcomes Network (MOON) ACL Reconstruction (ACLR): Onsite Follow-up
Rupture of Anterior Cruciate LigamentOsteoarthritisIn this study we will examine patients who have undergone unilateral ACL reconstruction surgery to determine which structural and functional characteristics of the knee two and ten years post reconstruction surgery, aspects of the original injury and repair, and patient characteristics are risk factors for osteoarthritis after ACL reconstruction surgery.

Sidus(TM) Post Market Clinical Follow-up (PMCF) Study
Non-inflammatory Degenerative Joint Disease (NIDJD)Avascular Necrosis3 moreThis post market clinical follow-up study is designed to confirm safety and performance of the Sidus Stem-Free Shoulder when used in hemi or total shoulder arthroplasty. The safety of the implant will be evaluated by monitoring the frequency and incidence of all kinds of adverse events. The performance will be determined by analyzing the implant survival, overall pain and functional performances (based on Constant & Murley score and ASES score), subject quality of life (EuroQol EQ5D) and radiographic parameters (e.g. radiolucencies, osteolysis, component migration) of study subjects who received the Sidus Stem-Free Shoulder. The Sidus Stem-Free Shoulder is not approved for use in the US.

Off-the-Shelf Splints Versus Occupational Therapy Splints for Treatment of Trapeziometacarpal Arthrosis...
Trapeziometacarpal (TMC) ArthrosisThe specific aim is to compare the effectiveness of Off-the-Shelf splints and splints provided by Occupational Therapy for treatment of trapeziometacarpal (TMC) arthrosis.

Post Market Clinical Follow Up of LEGION™ Primary TKS With VERILAST™
Degenerative Joint DiseaseLEGION™ Primary Total Knee System is CE-marked and marketed in all study regions. This study serves as post-market surveillance for LEGION™ Primary Total Knee System with the VERILAST™ bearing surface (OXINIUM™ femoral component with highly cross-linked polyethylene tibial insert). All study subjects will receive a LEGION™ Primary Total Knee System with VERILAST™ bearing surface and the results will be analysed against historical data from patients who received a Genesis II knee replacement.